Skip to main content

SC250 Metal Tube Variable Area

Metal construction

  • Indication by magnetic coupling.
  • Linear scales, calibrated in l/h, m3/h, kg/h, Tm/h, %, etc
  • Sizes DN-15 to DN-150.
  • Flowrate- Water: 2.5 l/h up to 180 m3/h.
  • Flowrate- Air: 0.07 Nm3/h up to 5,400 Nm3/h.
  • Low Pressure drop.
  • Standard Construction: in SS-316, PVC, & PTFE

Options

  • Local indication only.
  • 1 or 2 Alarm Settings.
  • 4-20mA Transmitter with 2 or 4 wire system.
  • Pneumatic transmitter 3-15 psi (0.2-1 Bar).
  • Intrinsically safe to ATEX standard EEx ia IIC T4/T6.
  • Flow totaliser.

Connections

  • Flanges DN-15 to DN-150 PN-40/PN-16 standard in steel or stainless steel-316
  • On request, flanges to ASA, BS 10, etc.
  • Screwed connections.
  • Sanitary screwed connections to DIN 11851.

Total Length Including Flanges

  • DN-15...DN-125: 250mm
  • DN-150: 300mm
SC250 Metal Tube Variable Area

Manufacturer:

Tecfluid

Advantages:

  • Variable area flowmeter for Liquids, Gasses and Steam
  • Robust construction
  • Versions suitable for harsh environments
  • 316SS, with plasatic and Hastelloy/Titanium versions
  • Vertical installation or, spring restrained horizontal versions
  • Custom Scales Alarm, 4-20mA and HART options